The results obtained employing this method are in excellent agreement with those obtained numerically in finite element modelling when tested using freestanding circular SiC diaphragms with residual tensile stress. The stress and modulus values are also in reasonably good agreement with those obtained from nanoindentation and wafer curvature measurements, respectively.